Mini, 0-115-230V, 115/230V, UL
High quality miniature open style toroidal transformers with tapped 0-115-230V, 50/60Hz primary windings suitable for connection to either 115V or 230V supply. Twin secondary windings may be connected in series or parallel or used independently.
Resin centre with through-hole for extra low build height. |
|
 |
|
|
Standard Power
Max Power
Connections |
|
Click here for series/parallel primary versions (62000 series)
- Very Small size and low weight compared with traditional stacked lamination types
- Extremely low level of radiated magnetic field
- Very low induced noise (hum)
- Very low iron loss
- Double insulated primary leads
- 100% electrical and flash tested
- High quality manufacturing and testing in accordance to:
EN61558, EN60742, EN60950, EN60065, VDE0551, VDE0550 and BS415
- Tested and Approved by KEMA to EN61558
- UL Recognised to UL506
Series 60000 - 0-115V-230V primary windings
Power VA |
Part No. |
Sec-Full Load Voltage |
Sec Current mA |
Open Circuit Voltage |
1.6 |
60000
60001
60002
60003
60004
60005 |
2x7
2x9
2x12
2x15
2x18
2x22
|
114
89
67
53
44
36 |
2x8.94
2x11.63
2x15.43
2x19.30
2x23.41
2x28.19 |
3.2 |
60010
60011
60012
60013
60014
60015
|
2x7
2x9
2x12
2x15
2x18
2x22
|
229
178
133
107
89
73 |
2x10.2
2x13.0
2x17.3
2x21.4
2x25.7
2x30.5 |
5.0 |
60020
60021
60022
60023
60024
60025 |
2x7
2x9
2x12
2x15
2x18
2x22
|
357
278
208
167
139
114 |
2x9.7
2x12.4
2x17.0
2x21.3
2x25.5
2x30.5 |
7.0 |
60030
60031
60032
60033
60034
60035
|
2x7
2x9
2x12
2x15
2x18
2x22
|
500
389
292
233
194
159 |
2x9.5
2x12.2
2x16.2
2x20.3
2x24.3
2x29.7 |
10.0 |
60040
60041
60042
60043
60044
60045 |
2x7
2x9
2x12
2x15
2x18
2x22
|
714
556
417
333
278
227 |
2x8.3
2x10.8
2x14.4
2x18.0
2x21.7
2x26.3
|
15.0 |
60050
60051
60052
60053
60054
60055 |
2x7
2x9
2x12
2x15
2x18
2x22
|
1,071
833
625
500
417
341 |
2x8.9
2x10.8
2x14.4
2x18.0
2x22.2
2x27.2
|
25.0 |
60060
60061
60062
60063
60064
60065 |
2x7
2x9
2x12
2x15
2x18
2x22
|
1,785
1,377
1,041
832
694
568 |
2x8.3
2x10.7
2x14.2
2x17.8
2x21.4
2x26.2
|
35.0 |
60070
60071
60072
60073
60074
60075 |
2x7
2x9
2x12
2x15
2x18
2x22
|
2,500
1,944
1,458
1,666
972
795 |
2x8.24
2x10.6
2x14.0
2x17.6
2x20.9
2x25.7 |
50.0 |
60080
60081
60082
60083
60084
60085 |
2x7
2x9
2x12
2x15
2x18
2x22
|
3,571
2,777
2,083
1,666
1,388
1,136 |
2x8.1
2x10.4
2x13.8
2x17.3
2x20.7
2x25.4 |
Mini Toroidal Transformer, Maximum Power (*), (@ 20°C)
Power VA |
(*)VA |
(*)Delta
Volts(%) |
(*)Delta
Temp. (°C) |
(*)Eff.
(%) |
(*)Rec.
fuse
(mA) |
1.6
3.2
5.0 |
2.0
3.7
5.5 |
60
80
80 |
30
40
40 |
60
50
50 |
32
50
63 |
7.0
10.0
15.0 |
7.5
12.0
16.0 |
70
60
60 |
40
45
40 |
60
60
65 |
80
100
125 |
25.0
35.0
50.0 |
-
-
- |
-
-
- |
-
-
- |
-
-
- |
-
-
- |
Mini Toroidal Transformer, Nominal Power (@ 20°C)
Power VA |
Dimensions
ODxIDxHT
(mm) |
Weight
(grams) |
Regulation
Delta Volts
(%) |
Delta
Temp.
(°C) |
Eff.
(%) |
No-load
(mA) |
230V
fuse
(mA) |
1.6
3.2
5.0 |
38.0x6.0x17.5
42.5x6.0x18.0
49.0x6.0x19.0 |
71
89
115 |
29
41
45 |
10
20
29 |
77
70
70 |
1.0
1.5
2.0 |
32
32
50 |
7.0
10.0
15.0 |
48.0x5.5x24
55.0x5.5x23.0
60.0x5.0x25.0 |
145
216
262 |
34
20
23 |
25
24
27 |
74
82
81 |
3.0
3.0
4.0 |
63
80
100 |
25.0
35.0
50.0 |
60.0x11.0x36.5
74.0x14.0x36.0
80.0x19.0x37.0 |
388
453
670 |
19
17.7
15.5 |
28
31
30 |
84
85
86 |
5.0
7.0
8.0 |
160
200
315 |
- Primary-Secondary test voltage 4.0 KV.
- Can be used for primary input 115V or 230V.
- Secondaries for parallel or series hook-up.
- Ambient operating temperature 60°C.
- Maximum Insulation Class A (105°C).
- Meets all requirements of Class E (125°C).
Important Installation Note
Each transformer is supplied with a resin centre, with through-hole for single bolt fixing. Under no circumstances should both ends of the fixing bolt contact a metal chassis or frame as this would create a "shorted turn" causing irreparable damage.
|
NULL
|